Thermal Design of the ZR-I Uterine Heat Ball Therapy Gun
DOI:
https://doi.org/10.54097/d69r6z71Keywords:
Uterine thermal ball therapy, treatment gun, thermal analysis, temperature control system, thermal safety, finite element simulationAbstract
The ZR-I Uterine Thermotherapy Device is a new type of thermotherapy device. This device is primarily used to treat symptoms of menorrhagia, and its core components include a treatment gun and a disposable treatment tip. This paper focuses on the structure and operating principles of this new device and conducts a systematic thermal analysis of the treatment gun. The analysis focuses on heat source distribution, heat conduction pathways, temperature control accuracy, and thermal safety. Through theoretical analysis, finite element simulation, and experimental validation, this study evaluates the thermal response characteristics of the treatment gun during a 126-second treatment cycle and their impact on treatment efficacy. The results indicate that the ZR-I treatment gun exhibits good thermal stability and temperature control accuracy within the range of 110°C to 132°C, enabling uniform thermal ablation of the endometrium and demonstrating high clinical value. This paper also compares the device with similar products both domestically and internationally, discussing its technical advantages and areas for improvement.
Downloads
References
[1] Khadawardi, K., Alharbi, H., Almujil, A., & Others. (2025). Exploring thermal balloon endometrial ablation with Foley's catheter: Management for heavy menstrual bleeding. SAGE Open Medicine, 13, 20503121251322325.
[2] Yingqiang, R., Zhonglian, H., Li, Y., & Others. (2026). Synergistic efficacy and safety evaluation of focused ultrasound ablation surgery combined with thermal balloon endometrial ablation in treating adenomyosis: A prospective controlled study. Gynecology and Minimally Invasive Therapy, 15(1), 58–64.
[3] Martignani, C., Biffi, M., Ziacchi, M., & Others. (2026). Current and emerging energy sources for atrial fibrillation ablation: A comparative analysis of clinical efficacy, safety, and procedural implementation. Journal of Clinical Medicine, 15(2), 751.
[4] Smith, J. R., & Williams, K. L. (2022). Thermal analysis and control systems in endometrial ablation devices: A review. Journal of Medical Engineering & Technology, 46(4), 287–295.
[5] Brown, A. C., & Davis, M. E. (2021). Finite element modeling of heat transfer in uterine balloon ablation. Annals of Biomedical Engineering, 49(8), 1892–1901.
[6] Zhang, Q. W., Li, H., & Chen, J. (2022). Clinical progress of endometrial ablation for treating menorrhagia. Chinese Journal of Obstetrics and Gynecology, 57(4), 312–316.
[7] Chen, J. Y., & Pu, Y. F. (2023). Efficacy observation of thermal balloon endometrial ablation for treating abnormal uterine bleeding. Journal of Practical Obstetrics and Gynecology, 39(1), 45–49.
[8] Wang, Y. S., Xu, F. L., & Liu, X. D. (2021). Development and thermal field distribution study of ZR Ⅰ uterine thermal balloon treatment instrument. Chinese Journal of Medical Instrumentation, 45(3), 267–271.
[9] Zhao, L. H., & Sun, X. Y. (2022). Comparison of therapeutic efficacy between thermal balloon endometrial ablation and hysteroscopic electroresection for menorrhagia. Chinese Journal of Clinical Obstetrics and Gynecology, 23(6), 578–581.
[10] Ren, Y. Q., Hu, Z. L., & Li, Y. (2025). Clinical study of focused ultrasound combined with thermal balloon ablation for treating adenomyosis. Journal of Chongqing Medical University, 50(2), 189–194.
[11] Zhou, X. H., & Wu, L. P. (2023). Safety evaluation of thermal balloon ablation for treating menorrhagia with high risk factors. Progress in Obstetrics and Gynecology, 32(3), 201–205.
[12] Chen, J., & Zhang, H. (2022). CEM43°C dose assessment for thermal damage in biological tissues during hyperthermia. Journal of Medical Biomechanics, 37(1), 112–117.
[13] Xu, F. L., & Wang, Y. S. (2021). Study on thermal stability of disposable medical devices. China Medical Device Information, 27(11), 23–27.
[14] Huang, L. J., & Yang, X. D. (2024). Long term efficacy follow up of thermal balloon ablation for treating adenomyosis. Chinese Journal of Practical Gynecology and Obstetrics, 40(2), 178–182.
[15] Wang, Z. L., & Liu, W. (2021). Finite element simulation and experimental validation of thermal field distribution in medical devices. Journal of Biomedical Engineering, 38(5), 923–929.
[16] Zheng, X. Y., & Liu, F. (2022). Clinical observation on the effect of thermal balloon endometrial ablation on ovarian function. Journal of Reproductive Medicine, 31(5), 623–627.
[17] Liu, W., & Wang, Z. L. (2021). Design of precision temperature control system for medical devices based on PID algorithm. Automation & Instrumentation, 36(4), 67–71.
[18] Sun, L. J., & Wang, W. (2022). Study on thermal efficiency optimization of heat source systems in medical devices. Mechanical Design & Manufacturing, (9), 145–149.
[19] Li, M. Y., & Zheng, X. F. (2021). Design and accuracy analysis of temperature control systems for thermal therapy devices. Medical & Health Equipment, 42(8), 32–36.
[20] Liu, X. D., & Xu, M. R. (2021). Application and thermal stability analysis of medical composite plunger pump in thermal balloon treatment instrument. Journal of Medical Biomechanics, 36(2), 156–161.